Pneumatic Cylinder,Pneumatic Valve,Air Cylinder,Air Treatment Units
RSS icon Email icon Home icon
  • Solenoid valve-Working principle

    Posted on April 13th, 2009 admin No comments

    A solenoid valve has two main parts: the solenoid and the valve. The solenoid converts electrical energy into mechanical energy which, in turn, opens or closes the valve mechanically. A Direct Acting valve has only a small flow circuit, shown within section E of this diagram (this section is mentioned below as a pilot valve). This Diaphragm Piloted Valve multiplies this small flow by using it to control the flow through a much larger orifice.

    Solenoid valves may use metal seals or rubber seals, and may also have electrical interfaces to allow for easy control. A spring may be used to hold the valve opened or closed while the valve is not activated.

    A- Input side
    B- Diaphragm
    C- Pressure chamber
    D- Pressure relief conduit
    E- Solenoid
    F- Output side

    Pneumatic Valve, Air Cylinder, Air Treatment Units, Pneumatic Accessories, Hydraulic Components, Pneumatic Cylinder.

    In the previous configuration the small conduit D was blocked by a pin which is the armature of the solenoid E and which is pushed down by a spring. If the solenoid is activated by drawing the pin upwards via magnetic force from the solenoid current, the water in chamber C will flow through this conduit D to the output side of the valve. The pressure in chamber C will drop and the incoming pressure will lift the diaphragm thus opening the main valve. Water now flows directly from A to F.When the solenoid is again deactivated and the conduit D is closed again, the spring needs very little force to push the diaphragm down again and the main valve closes. In practice there is often no separate spring, the elastomer diaphragm is moulded so that it functions as its own spring, preferring to be in the closed shape.From this explanation it can be seen that this type of valve relies on a differential of pressure between input and output as the pressure at the input must always be greater than the pressure at the output for it to work. Should the pressure at the output, for any reason, rise above that of the input then the valve would open regardless of the state of the solenoid and pilot valve.

    In some solenoid valvesthe solenoid acts directly on the main valve. Others use a small, complete solenoid valve, known as a pilot, to actuate a larger valve. While the second type is actually a solenoid valve combined with a pneumatically actuated valve, they are sold and packaged as a single unit referred to as a solenoid valve. Piloted valves require much less power to control, but they are noticeably slower. Piloted solenoids usually need full power at all times to open and stay open, where a direct acting solenoid may only need full power for a short period of time to open it, and only low power to hold it.